520-079-000 9/00 Model EB1-SM Type 3 Page 1
SERVICE AND OPERATING MANUAL
PRINCIPLE OF OPERATION
This ball check valve pump is powered by compressed air and is a 1:1 pressure ratio
design. It alternately pressurizes the inner side of one diaphragm chamber, while
simultaneously exhausting the other inner chamber. This causes the diaphragms, which
are connected by a common rod, to move endwise. Air pressure is applied over the entire
surface of the diaphragm, while liquid is discharged from the opposite side. The
diaphragm operates under a balanced condition during the discharge stroke, which
allows the unit to be operated at discharge heads over 200 feet (61 meters) of water
head.
Since the diaphragms are connected by a common rod, secured by plates to the
center of the diaphragms, one diaphragm performs the discharge stroke, while the other
is pulled to perform the suction stroke in the opposite chamber.
For maximum diaphragm life, keep the pump as close to the liquid being pumped as
possible. Positive suction head in excess of 10 feet of liquid (3.048 meters) may require
a back pressure regulating device. This will maximize diaphragm life.
Alternate pressuring and exhausting of the diaphragm chamber is performed by
means of an externally mounted, pilot operated, four-way spool type air distribution
valve. When the spool shifts to one end of the valve body, inlet air pressure is applied
to one diaphragm chamber and the other diaphragm chamber exhausts. When the spool
shifts to the opposite end of the valve body, the porting of chambers is reversed. The
air distribution valve spool is moved by an internal pilot valve which alternately
pressurizes one side of the air distribution valve spool, while exhausting the other side.
The pilot valve is shifted at each end of the diaphragm stroke by the diaphragm plate
coming in contact with the end of the pilot valve spool. This pushes it into position for
shifting of the air distribution valve.
The chambers are manifolded together with a suction and discharge check valve for
each chamber, maintaining flow in one direction through the pump.
INSTALLATION & START-UP
Locate the pump as close to the product being pumped as possible, keeping suction
line length and number of fittings to a minimum. Do not reduce line size.
For installations of rigid piping, short flexible sections of hose should be installed
between pump and piping. This reduces vibration and strain to the piping system. A
Warren Rupp Tranquilizer
®
surge suppressor is recommended to further reduce
pulsation in flow.
This pump was tested at the factory prior to shipment and is ready for operation. It
is completely self-priming from a dry start for suction lifts of 20 feet (6.096 meters) or
less. For suction lifts exceeding 20 feet of liquid, fill the chambers with liquid prior to
priming.
AIR SUPPLY
Air supply pressures cannot exceed 125 psi (8.61 bar). Connect the pump air inlet
to an air supply of sufficient capacity and pressure required for desired performance.
When the air line is solid piping, use a short length of flexible hose (not less than 3/4"
[19mm] in diameter) between pump and piping to eliminate strain to pipes. Use of a
Warren Rupp Filter/Regulator in the air line is recommended.
AIR INLET & PRIMING
For start-up, open an air valve approximately 1/2 to 3/4 turn. After the unit primes,
an air valve can be opened to increase flow as desired. If opening the valve increases
cycling rate, but does not increase flow rate, cavitation has occurred, and the valve
should be closed slightly.
Type 3
Model EB1-SM
Air inlet
IMPORTANT
Read these instructions completely, be-
fore installation and start-up. It is the
responsibility of the purchaser to retain
this manual for reference. Failure to com-
ply with the recommendations stated in
this manual will damage the pump, and
void factory warranty.
WARNING
Take action to prevent static sparking.
Fire or explosion can result, especially
when handling flammable liquids. The
pump, piping, valves, containers or other
miscellaneous equipment must be
grounded.
BEFORE OPERATION
Before pump operation, inspect all
gasketed fasteners for looseness caused
by gasket creep. Retorque loose fasten-
ers to prevent leakage. Follow recom-
mended torques stated in the card at-
tached to the new pump.
HAZARD WARNING
POSSIBLE EXPLOSION HAZARD can
result if 1, 1, 1,-Trichloroethane, Methyl-
ene Chloride or other Halogenated Hy-
drocarbon solvents are used in pressur-
ized fluid systems having Aluminum or
Galvanized wetted parts. Death, serious
bodily injury and/or property damage
could result. Consult with the factory if
you have questions concerning Haloge-
nated Hydrocarbon solvents.
®
WARREN RUPP
®
, INC., A Unit of IDEX Corporation • P.O. Box 1568 • Mansfield, Ohio 44901-1568 USA • (419) 524-8388 Fax (419) 522-7867 • www.warrenrupp.com
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - Model EB1-SM

520-079-000 9/00 Model EB1-SM Type 3 Page 1SERVICE AND OPERATING MANUALPRINCIPLE OF OPERATIONThis ball check valve pump is powered by compressed ai

Page 2 - Ball retainer

Model EB1-SM Type 3 Page 2 520-079-000 9/00CAUTIONIf a diaphragm fails the pumpedproduct or fumes can enter the airside of the pump. This side is e

Page 3

520-079-000 9/00 Model EB1-SM Type 3 Page 3Water in the compressed air supply can create problems such as icing or freezing ofthe exhaust air causi

Page 4 - TROUBLESHOOTING

Model EB1-SM Type 3 Page 4 520-079-000 9/00CAUTIONWhen removing capscrews onsuction or discharge valve retainer/cap, make sure all pressure onsucti

Page 5 - MAXIMIZE PUMP PERFORMANCE:

520-079-000 9/00 Model EB1-SM Type 3 Page 5WARNINGBEFORE PUMP OPERATION allexternal gasketed fasteners mustbe inspected for looseness causedby gask

Page 6

Model EB1-SM Type 3 Page 6 520-079-000 9/00REPAIR PARTS LIST and DRAWING Type 3 1 095-051-551 Body, Spool Valve 1 2 031-039-000 Sleeve & Spool

Page 7

520-079-000 9/00 Model EB1-SM Type 3 Page 71 Reduce quantity by 4 when used with dual ported manifold.2 Available in kit form. Order P/N 031-060-00

Page 8

Model EB1-SM Type 3 Page 8 520-079-000 9/00Optional FreestandingBaseDual Ported UnitsOnly©2000 Warren Rupp, Inc. All rights reserved.®Warren Rupp,